H10PM vs FieldPiece SRL8 R22 in the field
H10PM vs FieldPiece SRL8 R22 in the field
Переглядів: 205

Відео

Inficon Tek Mate vs Fieldpiece SRL8 with R22 in the field
Переглядів 30411 місяців тому
This shows how much more sensitive the Tek Mate is compared to the SRL8 on R22. The SRL8 is much better tuned for R410a and the Tek Mate is better tuned for R22. When these leak detectors on their respective gasses, you will never miss a leak.
Bacharach H10PM R22 PPM
Переглядів 5011 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors here: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
Fieldpiece SRL2 R22 PPM
Переглядів 3411 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
Inficon HLD4000 R22 PPM
Переглядів 2411 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
JB LD5000 R22 PPM
Переглядів 2911 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
Inficon DTek Select R22 ppm
Переглядів 6711 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
Inficon TekMate R22 PPM
Переглядів 4511 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
Fieldpiece SRL8 Motion Test
Переглядів 5211 місяців тому
Fieldpiece SRL8 Motion Test
Inficon HLD4000 R410a PPM
Переглядів 3011 місяців тому
Inficon HLD4000 R410a PPM
FieldPiece SRL8 R22 PPM
Переглядів 2211 місяців тому
FieldPiece SRL8 R22 PPM
Inficon TekMate Motion Test
Переглядів 4011 місяців тому
Inficon TekMate Motion Test
Inficon DTEK Select R410a PPM
Переглядів 10111 місяців тому
Inficon DTEK Select R410a PPM
Fieldpiece SRL8 finds small R410a leak in evaporator coil very quickly
Переглядів 10911 місяців тому
Fieldpiece SRL8 finds small R410a leak in evaporator coil very quickly
How to find large leaks
Переглядів 7811 місяців тому
How to find large leaks
Fieldpiece SRL2 R410a PPM
Переглядів 2011 місяців тому
Fieldpiece SRL2 R410a PPM
TIF XP1A R22 PPM (Failed test because of wind sensitivity)
Переглядів 1611 місяців тому
TIF XP1A R22 PPM (Failed test because of wind sensitivity)
UEI RLD15 R410a PPM
Переглядів 2211 місяців тому
UEI RLD15 R410a PPM
Inficon PercMate R410a PPM
Переглядів 1811 місяців тому
Inficon PercMate R410a PPM
UEI RLD15 R22 PPM
Переглядів 911 місяців тому
UEI RLD15 R22 PPM
JB LD5000 R410a PPM
Переглядів 1411 місяців тому
JB LD5000 R410a PPM
Fieldpiece SRL8 finds very small R410a leak
Переглядів 7811 місяців тому
Fieldpiece SRL8 finds very small R410a leak
PerkMate vs LD-5000
Переглядів 9011 місяців тому
PerkMate vs LD-5000
Inficon HLD4000 vs Fieldpiece SRL8 R410a PPM
Переглядів 5911 місяців тому
Inficon HLD4000 vs Fieldpiece SRL8 R410a PPM
Fieldpiece SRL8 showing poor sensitivity to R410a
Переглядів 1911 місяців тому
Fieldpiece SRL8 showing poor sensitivity to R410a
Prowler LD5000 R22 PPM
Переглядів 5211 місяців тому
Prowler LD5000 R22 PPM
Fieldpiece SRL8 R410a PPM
Переглядів 4711 місяців тому
Fieldpiece SRL8 R410a PPM
TIF ZX1 R22 PPM
Переглядів 2311 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
TIF ZX1 R410a PPM
Переглядів 4011 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0
TIF XP1A R410a PPM
Переглядів 17011 місяців тому
Download the free pdf version of my leak detector report where I test all the hvac leak detectors: www.dropbox.com/scl/fo/jut6cfhq5ka2v3ka9avvg/h?rlkey=ma4t2gfq3j6sown6j7ngikeuu&dl=0

КОМЕНТАРІ

  • @cowlumbus
    @cowlumbus 2 дні тому

    It's the pipe with a UV inhibitor on the outside and poly inside. It's the chemical used for UV which is silly because you should have a proper cover on it anyways.

  • @AaronBenyamin
    @AaronBenyamin 3 дні тому

    Lot of knowledge

  • @wydryfly
    @wydryfly 5 днів тому

    Why no class action on this product? Too many are failing and is a widespread sign of a defective product. It’s costing homeowners and businesses millions in repairs. Had to rip my interior walls out to replace our line sets. Very upset and frustrated. Class Action needs to happen!

  • @TodKarlson
    @TodKarlson 6 днів тому

    I have a Bryant Plus 90 furnace built 2004, making it 20 years old, but I’m not made of money, so I’m trying to keep it working. Anyway, several weeks ago I was having rusty water leaking out even when not running the AC. Turns out these high efficiency furnaces generate condensate both when cooling & heating. The reason why they have PVC exhaust pipes is not just because the installers are being cheap & they can get away with it because the high efficiency makes the exhaust gas so cool compared to 80% efficiency furnaces, it’s actually because this condensation is corrosive to the galvanized chimney material, so you’re not being cheap using PVC, you actually MUST use PVC or it will get corroded very quickly. Anyway, I opened the bottom & discovered water dripping from the drain line for the condensate trap & the hard pipe to the floor drain was also plugged, so I replaced the drain line with a piece of clear poly tubing & sucked out the drain pipe with my shop vac. Black rusty debris versus the usual organic “snot” that this evolution usually produces. Now I’m having an issue with flame rollout. So, I did everything including pulling out the primary & secondary heat exchanger. Everything is surprisingly clean & the heat exchanger is not cracked, but after watching this video & hearing about how this brand/model of secondary heat exchanger is practically NON-cleanable, I’m realizing that I will probably need to replace it, but I’m going to stubbornly try to clean it while I’m waiting for the new one to arrive. $700 is better than $20k. Thanks for posting this video which was a great help for my decision-making.

  • @stevenbrice1681
    @stevenbrice1681 10 днів тому

    My unit sits on cinder blocks and the blocks are on a plastic base. I get a serious hum from the new Goodman system. Maybe I will try these things out.

  • @oshitomaha
    @oshitomaha 11 днів тому

    I had my Della mini split installed 6 months ago (3 zones) and I noticed the line set leaking on the wall. Does anyone know if this would affect the condenser?? Should I get it checked out?

  • @richport5593
    @richport5593 12 днів тому

    Good stuff

  • @cowlumbus
    @cowlumbus 13 днів тому

    Are these line sets used for traditional HVAC install or just on the Mini Splits?

  • @brendandevlin7245
    @brendandevlin7245 15 днів тому

    I have an old 4 Ton R22 split system, the compressor rotted through releasing all the R22. The Attic is very in accessible, so I opted to purchase a new 407C compressor and leave the coil alone. Anybody see any problems with this strategy ? Now I need to get the system charged ? Can I do this myself ? Where can I rent the gear ?

  • @pharoahmonk50
    @pharoahmonk50 23 дні тому

    Great video. Great conversion!

  • @BushmansAdventures
    @BushmansAdventures 25 днів тому

    I’m running a Frantz bypass oil filter on my 1990 Mazda B2200 pickup. It sees severe duty , long hot hours, dusty logging roads , dusty mine roads, etc. I run either LiquiMoly or redline 5w40 full synthetic in it. Main oil filter is a Donaldson filter, bypass is a Frantz Truck has 1,375,324 KM’s on it. I run 25,000 oil change intervals . Main filter gets changed at 12,500 km intervals. Oil runs clear and clean . I send off oil samples often and they tell me the oil is good for another 75,000 KM’s plus Bypass filters are an excellent way to get millions of KM’s out of your truck / car. Not sure why you had issues in your car, using the Frantz filter??????? Something not right here ….. bypass filters extend your engine life by hundreds of thousands of KM’s or more. 🤷???

  • @cj-bd3ql
    @cj-bd3ql 25 днів тому

    Highly trained to pour oil in a cup😮

    • @cj-bd3ql
      @cj-bd3ql 25 днів тому

      A scale!!! you mean a measuring cup

  • @misaghtabibzadeh7641
    @misaghtabibzadeh7641 Місяць тому

    Hello, We have serious issue with our New installed AC, I would really appreciate if you could advise on what is going on. I hired a contractor to replace our old R22 AC unit with a brand new Merit seer 14 Lennox and a new Lennox coil last year. After running a few times, sometime the compressor started acting up and from working normal it was switching to abnormal mode which was making a loud noise like buzzing noise and not providing cold air (fan was running all the time). Contractor who installed it, has checked and replaced the whole unit a new one. However, the new unit also after a few days ended up with the same issue!!! P.s. before installing the unit, they've vacuumed the line for 1 hour and also they have changed the whole supply line with a new 3/4" line. I have checked the power supply line 240-244v is always available at the AC disconnect. The contractor has attached a gauge to the unit and when buzzing noise occurred the pressure of the liquid side has dropped and gas went up. I took a video and uploaded in the link below) As I searched it seems that noise is from the compressor internal relief valve which is blowing. But this issue happens erratically and when I reset the compressor from the thermostat it goes away till next time. The previous unit (defective) which was replaced with this new one at end after a few cycles the compressor seemed to work (there was no compressor sound and no cold air) and only fan was running. We really wonder what's the issue? I have uploaded two videos of normal working mode and noisy mode Normal mode: streamable.com/ighm0i Noisy: streamable.com/gqk514

  • @RaulSaint-l8e
    @RaulSaint-l8e Місяць тому

    Hi, how do you turn it back on?

  • @jamesmcginness9074
    @jamesmcginness9074 Місяць тому

    What is the name of the white insulation in video? I heard the company that made them were in france and they were recalled. I am having same issues

  • @toddhare8225
    @toddhare8225 Місяць тому

    I work for Reflectix, the company that manufacturers the product that you are using here. HVBB48075 - Big Bubble. This product is an R6 when applied directly to the duct. However, you do need to apply a 3/4" air space against the duct to achieve an R8. Nice job though!

  • @powersguo
    @powersguo Місяць тому

    ❤❤❤

  • @MichaelCzajka
    @MichaelCzajka Місяць тому

    Sounds like you need to do an oil analysis. Microscopy would be helpful too. A normal oil filter will only filter to ~40 microns. A bypass oil filter will filter to ~2 microns or less. You can hear the difference: Better filtration = A quieter engine Wear is reduced: Particles 2~22 microns are the main cause of wear in an engine However, we still change our oil at the regular recommended intervals because the additive package is depleted e.g. TBN (Total Base Number) is usually very low: Alkalinity is depleted The wear on our engine is minimal and it uses no oil so we know it's not doing any harm. We probably could run the oil for longer without any harm. We've been running bypass filters over 4,000,000 km in many different cars. 🙂

  • @how2dostuff757
    @how2dostuff757 Місяць тому

    Where can I get this? Can’t find with any retailer. Thanks!

  • @christophermatthews4597
    @christophermatthews4597 2 місяці тому

    The singing and the ringing through the vein was insane and a pain in my brain

  • @busyonthefarm
    @busyonthefarm 2 місяці тому

    Thank you for performing this test. I'm replacing some parts in an ice maker. I'm comfortable with the brazing but do not have a nitrogen setup. I do have a mig setup with argon/co2 however. I knew the argon would be up to the task but was unsure if the co2 would be compatible. This settled my concern.

  • @BrandonPoulton
    @BrandonPoulton 2 місяці тому

    Genius. Best test method on UA-cam! You should go full project farm!

  • @sevakshir3612
    @sevakshir3612 2 місяці тому

    LG compressors just jam up not pistons fault. If that was Copland this wouldn't happen.

  • @VashtheReapr
    @VashtheReapr 2 місяці тому

    You have the sensetivity on medium on the navac might pick up a little better if you put it on high

  • @michaelmckenna9022
    @michaelmckenna9022 2 місяці тому

    What does 45 Min on a compressor label for oil quantity mean?

    • @NathansHVAC
      @NathansHVAC 2 місяці тому

      45 oz of mineral oil. That only works for the old chlorine based refrigerants. You need polyolester for the new fluorine based ones.

    • @michaelmckenna9022
      @michaelmckenna9022 2 місяці тому

      @@NathansHVAC Wow, thanks. Decided to get my Universal and do a little refrigeration. First I'll upgrade my old Bryant. The furnace and AC have been working great for 28 years. So far I rebuilt the furnace completely. Now I will rebuild the AC and retrofit it with an HFC. The biggest problem is deciding which one, everyone has an opinion.

  • @michaelmckenna9022
    @michaelmckenna9022 2 місяці тому

    R-421a or R-407c?

    • @NathansHVAC
      @NathansHVAC 2 місяці тому

      All the drop in refrigerants have some butane to return the old mineral oil.

  • @testdepth377
    @testdepth377 2 місяці тому

    Do those current limiters work in all ECM motors? What is the motor size difference between the 20A and 30A motors? I recently had a 1/3hp motor go bad. Which limiter would have been the correct one? Current limiter acts as a fuse.

  • @kenaddams3604
    @kenaddams3604 2 місяці тому

    Thank you for the video.

  • @ThreePhaseHigh
    @ThreePhaseHigh 2 місяці тому

    I have never taken out the 22. I just dropped the replacement refrigerant right in on top of it. The pressures are practically the same. It works good no problem and it saves you and the customer a lot of time and money.

  • @karhukivi
    @karhukivi 2 місяці тому

    If you know what the resistance of the solenoid coil should be (typically 1.4 ohms) you can check the coil resistance. Mine is reading 0 ohms now so I know it is shorted out and burner doesn't start, nothing happens in fact.

  • @davidlong1540
    @davidlong1540 2 місяці тому

    Mine goes from 40db to 80db at the return vent, with or without the grill mounted.

  • @donnasimonds4215
    @donnasimonds4215 2 місяці тому

    How much does it cost to convert oil to gas? Estimated

  • @williambrown4293
    @williambrown4293 2 місяці тому

    it's the insolation not the copper

  • @bryanfowler2039
    @bryanfowler2039 2 місяці тому

    Can I do this with a wooden pallet?

  • @saw288
    @saw288 3 місяці тому

    Very interesting 👍

  • @daveed4475
    @daveed4475 3 місяці тому

    Thanks! I'll try this.

  • @wendyfoster9888
    @wendyfoster9888 3 місяці тому

    Will that make your ductwork more quiet. Mine is noisy

  • @zaction10
    @zaction10 3 місяці тому

    Holy crap, was that an 8” hole cutout for the entire ain’t handler? That removal of the horizontal pan didn’t help at all if that was the only cutout. I’ve see undercutting of top takeoff on duct but never something that severe. Nuts out there. I like that blower thing for the sanding grit.

  • @CreativeMaintenanceSolutions
    @CreativeMaintenanceSolutions 4 місяці тому

    So I have an accumulator and I'm changing a 5 ton r22 unit to r407c. Was just going to RX flush, blow out with nitrogen, then replace with new compressor that comes with POE oil. I guess I dont have to take the accumulator out and dump out any oil?

    • @NathansHVAC
      @NathansHVAC 3 місяці тому

      If you are doing the compressor, might as well take out the accumulator. Also paint it

  • @dpark189
    @dpark189 4 місяці тому

    i was curious about this and this seems to be a good conclusion, thank you

  • @leilanirocks
    @leilanirocks 4 місяці тому

    Wow. Cool video!

  • @NytefogNJ
    @NytefogNJ 4 місяці тому

    Anyone find out where to find the trigger/adapter for the paintball gun co2 tank?

  • @JohnLee-db9zt
    @JohnLee-db9zt 4 місяці тому

    Aren’t you concerned the fiberglass liner will introduce tiny fiberglass dust into the air and you’ll be breathing that in?

    • @elic.2443
      @elic.2443 3 місяці тому

      When the lining starts to tall apart from air moving over it for years....🙄

  • @A2J_Tim
    @A2J_Tim 4 місяці тому

    What kind of oil were you using? if you are using garbage Oil, yea I agree filtering it more isnt going to make the oil last longer, the cheap oils will break down alot sooner than a high quality synthetic. The key is using high grade synthetic and filtering.

  • @chrisspanyer1525
    @chrisspanyer1525 4 місяці тому

    Exactly what I was looking for. Thank you

  • @lasyone74
    @lasyone74 4 місяці тому

    Great video. It's been over a year since you posted. Have you tested the ILD-200? THANKS

  • @user-sy5ef8yr7d
    @user-sy5ef8yr7d 4 місяці тому

    Nutshell do you recommend it !?

  • @NathansHVAC
    @NathansHVAC 4 місяці тому

    Watch out for the fake Nissan NS-3 fluid bottles on ebay and Amazon. There are a ton of them for sale now. Go to alibaba to see where they are comming from and what they look like.

  • @antonisautos8704
    @antonisautos8704 4 місяці тому

    CVT fluid and filter should be done every 30K to 40K max miles. They are very sensative to maintenance. You eneded up replacing yours. Probably because it was wore out from extended service intervals. Use only the fluid from the manufacturer as well. I see in your video you did do that. All that anti seize is not necessary on those bolts. Its odd that they appeared tapered. But you said 2 were stripped out. You have to check torque specs.

  • @AMERICANPRIDE1100
    @AMERICANPRIDE1100 4 місяці тому

    Did you use the same size tip for normal brazing